1.
Journal of Medical Postgraduates ; (12): 706-709, 2014.
Article in Chinese | WPRIM | ID: wpr-453320

ABSTRACT

Objective This study was to analyze the causes of the complications of ultrasound -guided percutaneous renal bi-opsy in children . Methods We retrospectively analyzed the complications of ultrasound-guided percutaneous renal biopsy in 236 children along with the age, sex, sample length, times of puncture, and types of disease of the patients .We used the binary Logistic regression model to analyze the influences of various factors on the post -biopsy complications . Results After renal biopsy , 22 (9.3%) of the patients experienced various degrees of but no severe complications .The incidence of complications was significantly correlated with the sample length (P<0.05), but not with the age, sex, sample length, times of puncture, and types of disease of the patients. Conclusion Ultrasound-guided percutaneous renal biopsy is an effective diagnostic method for children , with a high suc-cess rate and a low incidence of complications .And the incidence of complications can be reduced by improving the skills of puncturing and accuracy of ultrasound positioning .

2.
Journal of Medical Postgraduates ; (12): 710-712, 2014.
Article in Chinese | WPRIM | ID: wpr-453319

ABSTRACT

Objective Evaluation of left ventricular ( LV) function has great clinical significance in patients with early chro-nic kidney disease (CKD).The study was to evaluate whether two-dimensional speckle tracking imaging (2D-STI) technique can offer additional information of cardiac dysfunction in early CKD patients . Methods Conventional echocardiography and 2D-STI echocar-diography were performed in CKD group of 20 patients at stage Ⅱ-Ⅲ and control group of 20 healthy volunteers .LV structure and function were evaluated by conventional echocardiography .Multidirectional strain , strain rate and LV twist parameters were analyzed by 2D-STI technique. Results There was no statistical difference in conventional echocardiographic parameters such as left atrial diam -eter, end-diastolic LV diameter and ejection fraction between CKD group and control group .By applying 2D-STI technique, CKD group had significantly decreased value of global longitudinal strain (-19.8 ±2.4)%and strain rate(-1.1 ±0.3)S-1 in comparison to control group(-22.6 ±2.1)%、( -1.8 ±0.2)S-1, along with significant increase in the values of maximum LV rotation (11.6 ± 4.4)°and LV twist(19.6 ±3.8)°in comparison to control group(8.2 ±3.7)°、(13.5 ±3.6)°(P0.05). Conclusion 2D-STI can detect subclinical LV dysfunction sensitively in early CKD patients .

3.
Chinese Journal of Ultrasonography ; (12): 416-419, 2012.
Article in Chinese | WPRIM | ID: wpr-425739

ABSTRACT

Objective To investigate the correlation between elasticity obtained with acoustic radiation force impulse(ARFI) and blood perfusion obtained with contrast enhanced ultrasound(CEUS) in renal carcinoma.Methods Tweenty-four patients with renal carcinoma confirmed by operation and pathology underwent ARFI and CEUS sequentially,got preliminary information of elasticity,size and border with virtual touch tissue imaging (VTI),shear wave velocity (SWV) of tumor and renal cortex at least 2centimeters from the tumor margin were measured with virtual touch tissue quantification (VTQ),and then the imaging characteristics were analyzed with time intensity curve (TIC).The elasticity obtained with ARFI were compared with the blood perfusion obtained with CEUS.ResultsTotally 24 cases included 18 renal cell carcinomas,3 papillary renal cell carcinomas,2 chromophobe cell renal carcinomas and 1 rena1collecting duct carcinoma.In VTI,18 appeared darker,4 appeared brighter,and 2 had the same brightness as renal cortex.The SWV of tumor and renal cortex were (2.47±0.61)m/s,(2.10±0.94) m/s,respectively,19 were stiffer than renal cortex (79.2%),among which 18 appeared hyper-enhancement and 1 appeared hypo-enhancement;5 were softer than renal cortex (20.8%),among which 2 appeared hyper-enhancement and 3 appeared hypo-enhancement in CEUS.Tumors with different elasticity had different enhancement,stiff cases appeared hyper-enhancement,soft cases appeared hypo-enhancement (P < 0.05).Conclusions There is correlation between elasticity obtained with ARFI and blood perfusion obtained with CEUS in renal carcinoma

4.
Chinese Journal of Ultrasonography ; (12): 617-620, 2011.
Article in Chinese | WPRIM | ID: wpr-416500

ABSTRACT

Objective To investigate the value of contrast enhanced ultrasound(CEUS) with microbubbles targeted to vascular endothelial growth factor receptor type 2 (VEGFR2) for imaging tumor angiogenesis in murine tumor models.Methods Established human renal cell carcinomas(RCC) subcutaneous xenograft tumor model in nude mice,microbubbles targeted to VEGFR2(MBV) was prepared,control microbubbles(MBC) and MBV were injected respectively in each mouse,the intensity of each microbubble was compared,the expressions of VEGFR2 in tumors were tested by immunohistochemistry.Results CEUS imaging showed the intensity of MBV and MBC was (6.50±1.43)dB,(2.59±0.99)dB,respectively.There was significantly higher intensity when using MBV compared with MBC (P<0.01).The time to wash out was longer in MBV contrast group compared with MBC group.Immunohistochemistry showed VEGFR2 was highly expressed in novel vessel walls.Conclusions Contrast microbubbles targeted to VEGFR2 can specially enhance the images of RCC and has tremendous significance in the assessment of angiogenesis.

5.
Chinese Journal of Urology ; (12): 258-261, 2011.
Article in Chinese | WPRIM | ID: wpr-412697

ABSTRACT

Objective To discuss the imaging characteristics of chromophobic cell renal carcinoma (CCRC) and study the features on the contrast-enhanced ultrasound (CEUS). Methods The CEUS features of CCRC in 28 cases identified by pathology were reviewed. The blood supply and enhancement characteristic were observed and analyzed on time intensity curve parameters. Results The 28 cases of CCRC showed poor blood supply in contrast with the renal cortex. The CCRC presented with heterogeneity enhancement, part of the tumor took on a high wash-in and wash-out, and enhanced less intense than the surrounding renal cortex. The actinomorphous strong echo of the tumors might be revealed with CEUS in 15 cases (54%). The time intensity curve analysis demonstrated that the CCRCs' difference of peak intensity and area under the curve were lower than the renal cortex (P<0.05), but arrival time, time-to-peak and slope of ascending curve were higher than the renal medulla (P<0.05). Conclusion The actinomorphous enhancement and poor blood supply in the tumor of CEUS could provide diagnostic evidence for CRCC.

6.
Chinese Journal of Ultrasonography ; (12): 10-13, 2011.
Article in Chinese | WPRIM | ID: wpr-384439

ABSTRACT

Objective To evaluate whether global 2-dimensional strain imaging can offer additional benefit over conventional echocardiography to detect subclinical myocardial damage in patients with chronic kidney disease(CKD). Methods Conventional echocardiography and global 2-dimension strain imaging were performed in 39 patients with CKD [23 men and 16 women,mean age (45.6± 14.6) years] and 29 control subjects. Twenty patients had CKD stage 2 or 3(group 1 ) and nineteen patients had CKD stage 4 or 5(group 2). Left ventricular structure and function were evaluated by conventional echocardiography. Global longitudinal and circumferential strain and strain rate were analyzed. Results There were no differences in ejection fraction and fraction shortening between CKD patients and controls. Compared with controls, CKD groups had significantly decreased value of global longitudinal strain and strain rate. Global longitudinal strain decreased from - (23.8 ± 3.1 ) % in controls to - ( 18. 5 ± 2.4) % in group 1 and to - (15.2 ± 3.2) % in group 2 ( P <0. 001 ). Compared with controls, there was no difference in global circumferential strain and strain rate between group 1 and controls, but global circumferential strain and strain rate of group 2 was reduced [ - (17.1± 3. 0) % vs -(21.2±2.8)%, P<0.05;-(1.0±0.2)% vs -(1.3±0.3)%, P<0.05]. In correlation analyses, global longitudinal strain was positively related to eGFR( r =0. 376, P <0. 001 ) and inversely related to left ventricular mass index( r = - 0. 473, P <0.01). Conclusions Global 2-dimensional strain imaging may represent a useful tool for the assessment of subclinical myocardial dysfunction in patients with CKD.

7.
Chinese Journal of Ultrasonography ; (12): 404-407, 2010.
Article in Chinese | WPRIM | ID: wpr-389659

ABSTRACT

Objective To analyze the misdiagnosis reasons in renal tumors with contrast-enhanced ultrasound (CEUS) and to improve cognition on CEUS. Methods Two-hundred and eighty-five cases were compared with pathology, the images in 22 cases misdiagnosed on CEUS were reviewed retrospectively and the reasons were analyzed. Results The diagnosis accuracy and misdiagnosis rate of CEUS were 92. 28 % (263/285) and 7. 72%(22/285), respectively. In these 22 cases, 9 cases misdiagnosed as renal cell carcinoma (RCC) were conformed by pathology as renal angiomyolipoma(RAMD), showed 5 cases "fast wash-in and fast wash-out", 4 cases "fast wash-in and slowly wash-out". Seven cases were conformed as RCC, in which 5 were misdiagnosed as RAML, showed 4 cases "fast wash-in and slowly wash-out", 1 cases "simultaneously wash-in and simultaneously wash-out", and 2 were misdiagnosed as renal cyst with no enhancement founded. Four cases misdiagnosed as hematoma were conformed as pyelo-carcinoma, with no enhancement founded in renal pelvis. The remaining 2 cases misdiagnosed as inflammatory pseudotumor were conformed as RCC, showed "fast wash-in and slowly wash-out". Conclusions With the high diagnosis accuracy,CEUS is an important method in diagnosis of renal tumors. Analyzing the misdiagnosed reasons may improve the cognition on CEUS and decrease the misdiagnosis.

8.
Chinese Journal of Ultrasonography ; (12): 693-696, 2010.
Article in Chinese | WPRIM | ID: wpr-387723

ABSTRACT

Objective To explore the value of contrast-enhanced ultrasound(CEUS) in the diagnosis of hematoma and active hemorrhage of renal trauma. Methods Totally 28 patients with renal trauma were examined by conventional ultrasound and CEUS,respectively,including 24 cases caused after renal biopsy,4closed trauma. The detectability of renal hematoma and active hemorrhage with these two methods were compared. All patients were identified by CT or follow-up studies with ultrasound. Results The detectability of renal hematoma with conventional ultrasound and CEUS were 67. 86% (19/28), 92. 86%(26/28), respectively. There was statistically different for detectability in the diagnosis ( P <0.05), and the extent of hematoma was more obvious with CEUS. CEUS diagnosed 7 of 26 were renal hematoma with active hemorrhage,which were difficult to be detected with conventional ultrasound. For renal hematoma,the features of CEUS were no enhancement found in every phase; for renal hematoma with active hemorrhage,the contrast agents overflowed from injured blood vessels and formed irregular remarkable enhanced regions. Conclusions CEUS is useful in diagnosing hematoma and identifying the extent and active hemorrhage of renal trauma,in addition,CEUS is valuable in detecting complications after renal biopsy.

9.
Chinese Journal of Ultrasonography ; (12): 783-786, 2010.
Article in Chinese | WPRIM | ID: wpr-387234

ABSTRACT

Objective To assess the differential diagnosis and characteristics of renal benign and malignant tumors with three-dimensional contrast-enhanced ultrasound (3D-CEUS). Methods Totally 68 patients with renal tumors were examined by conventional ultrasound and two-dimensional contrastenhanced ultrasound(2D-CEUS). 3D imaging was reconstructed from 2D imaging, the differential diagnosis of renal tumors with 3D-CEUS was analyzed by comparing with 2D-CEUS. All patients with renal tumors were proved by operational pathology. Results Eighteen patients with renal benign tumors mostly displayed equal or low enhancement, showed "slowly in and slowly out" with 2D-CEUS, while displayed regular peripheral and internal vessels with 3D-CEUS. Fifty patients with renal malignant tumors mostly displayed high enhancement, showed "rapidly in and rapidly out" with 2D-CEUS,displayed winding peripheral vessels and disordered internal vessels with 3D-CEUS. 3D-CEUS may display the vascular characteristics of tumors and showed superior imaging quality to 2D-CEUS ( P < 0.05). Conclusions 3D-CEUS can display the vascular characteristics of tumors and their spatial positions, it plays an important role in differential diagnosis between renal benign and malignant tumors.

10.
Chinese Journal of Ultrasonography ; (12): 14-16, 2009.
Article in Chinese | WPRIM | ID: wpr-396963

ABSTRACT

Objective To assess the coronary flow reserve in the patients with systemic lupus erythematosus(SLE)by transthroracic echocardiography(TTE).Methods Coronary sinus blood flow of 24 SLE patients and 18 matched healthy controls were assessed by TTE.The coronary flow reserve was calculated as the ratio of hyperemic to baseline blood flow.Hyperemia was induced by intravenous administration of dipyridamole.Results Adequate recordings of blood flow in the coronary sinus under both conditions were obtained by TTE in all study subjects.Patients with SLE were found to have significantly decreased coronary flow reserve comparing with normal SUbiects(1.55±0.21 versus 2.51±0.33.P<0.01).Conclusions Coronary flow reserve can be measured by TTE in SLE patients,Coronary flow reserve is impaired suggesting that SLE patients may have subclinical coronary artery disease.

11.
Chinese Journal of Ultrasonography ; (12): 67-70, 2009.
Article in Chinese | WPRIM | ID: wpr-396955

ABSTRACT

Objective To study the haemodynamics changes in the proximal upstream artery caused by different degrees of abdominal aorta extremity stenosis.Methods The lateral walls of the abdominal aorta extremity were pinched with the vascular clamp to achieve 1/4,1/2 and 3/4 stenosis or occlusion in 6 juvenile susscrota domesticas,the velocity tracing of the proximal artery recorded,and the parameters of the peak systolic velocity(PSV)and minimum diastolic velocity(MDV)were obtained and statistically analyzed for their correlation with different degrees of abdominal aorta extremity stenosis.Results The diastolic velocity tracing vanished when stenosis reached a certain degree,the needle ridge and low amplitude diastolic velocity tracing emerged when stenosis to a certain extent,and only the needle ridge was present when the abdominal aorta extremity was completely obstructed.PSV reduced with the aggravation of stenosis.Conclusions The proximal upstream artery systolic ridge caused by abdominal aorta extremity stenosis tends to be acUminate,which indicates serious stenosis of the downstream artery.The systolic needle ridge and the absence of diastolic velocity tracing would suggest a complete obstruction of the blood stream in the downstream lumina.

12.
Chinese Journal of Ultrasonography ; (12): 541-544, 2009.
Article in Chinese | WPRIM | ID: wpr-394267

ABSTRACT

Objective To study the formations of several ridges in peripheral artery velocity tracing. Methods The experimental models of constrainting limb and adrenaline were performed in 6 juvenile susscrota domesticas,tbe variations of the external lilac artery velocity tracing observed,and the parameters of peak systolic velocity (PSV), minimum post-systolic velocity (MPV), peak diastolic velocity(PDV) and end diastolic velocity(EDV) were obtained. Results With the increase of downstream circulation resistance, systolic waveshape inclined to acumination, MPV gradually degraded to zero and negatively increased subsequently, diastolic wave amplitude lowered, and EDV gradually decreased to zero. The stronger vasoconstriction was, the more striking the variations were. Conclusions Cardiac ejection forms systolic dominant wave, post-systolic backward ware is the result of backstreaming because of elastic recoil of downstream artery,and diastolic forward ware is the result of blood transient acceleration caused by elastic recoil of upstream artery. Systemic vascular resistance has significant effect on diastolic waveshape,and the occurrence of post-systolic backward ware implies downstream circulation resistance obviously increases.

13.
Chinese Journal of Ultrasonography ; (12): 122-124, 2009.
Article in Chinese | WPRIM | ID: wpr-396132

ABSTRACT

Objective To investigate the source of the blood flow through ventricular septum in normal subject caused by slice-thickness artifact in echocardiography. Methods Echocardiography was performed in 50 normal subjects without ventricular septum defect by two models of echocardiography unit equipped with two models of transducer, observing the conditions and sections in which the blood flow through ventricular septum could be detected. Results The blood flow through ventricular septum was detected in 8 normal subjects using the certain model of echocardiography unit,especially in parasternal four chambers section and parasternal irregular sections, while the blood flow through ventricular septum wasn't detected in the other 42 subjects by any echocardiography unit. The blood flow through ventricular septum was caused by coronary vessel in atrioventrieular groove proved by combining dynamic observation with anatomy analysis. Conclusions The blood flow through ventricular septum in normal subjects, a kind of slice-thickness artifact in echocardiography,is caused by coronary vessel in atrioventricular groove mapped into intact ventricular septum.

14.
Chinese Journal of Ultrasonography ; (12): 869-871, 2008.
Article in Chinese | WPRIM | ID: wpr-398071

ABSTRACT

Objective To investigate the value of the diagnosis of contrast-enhanced ultrasound(CEUS) in renal tumors. Methods Nineteen patients with hyperechoic renal tumors detected by CEUS underwent resection for suspected renal malignant and benign tumors. The characterization of hyperechoic renal tumors on CEUS was evaluated. Results Histopathologic results of resected lesions showed benign tumors in 11 patients with angiomyolipoma and malignancy in 8 patients with clear cell carcinoma. Six patients with angiomyolipoma showed rapid wash in contrast enhancement and slow wash out on all tumor and focal tumor (6/11). One patient with angiomyolipoma was observed in rapid wash in and wash out (1/11). Four patients with angiomyolipoma showed rapid wash in and negative contrast enhancement after rapid wash out(negative contrast enhancement compared to renal cortex,4/11). Five patients with clear cell carcinoma showed rapid wash in and wash out (5/8). Two patients with clear cell carcinoma showed rapid wash in and delayed wash out (2/8). One patient with showed no enhancement on CEUS (1/8). The pseudocapsule could be seen at 5 patients with clear cell carcinoma. Wash in enhancement and wash out on clear cell carcinoma were significant in comparison to these of angiomyolipoma (P<0.05). Wash in enhancement,delayed wash out and negative contrast enhancement were no significant between clear cell carcinoma and angiomyolipoma (P>0.05). Conclusions CEUS is useful for discriminating between benign and malignant renal tumor.

15.
Chinese Journal of Ultrasonography ; (12): 994-997, 2008.
Article in Chinese | WPRIM | ID: wpr-397547

ABSTRACT

Objective To study the common femoral artery haemodynamics caused by different degrees of abdominal aorta extremity stenosis.Methods The lateral walls of abdominal aorta extremity were pinched with vascular clamp resulting in 1/3,1/2,2/3,3/4 stenosis by turns in 6 juvenile susscrota domesticas.The parameters of peak systolic velocity(PSV),minimum diastolic velocity(MDV),PSV/MDV(S/D)and MDV/PSV(D/S)of common femoral artery were obtained and their correlations with degrees of abdominal aorta extremity stenosis were confirmed by statistical analysis.Results The backwardware vanished or turned to forwardware when stenosis achieved certain degree.PSV had significant negative correlation with stenosis degree(R=0.985,R2=0.969),but D/S had significant positive correlation with stenosis degree when stenosis degree exceed 1/3(R=0.918,R2=0.843).Conclusions It can be concluded there is proximal stenosis disease and change of distal effective circulating blood volume according to the Doppler velocity tracing analysis.PSV and D/S are valuable parameters,however waveform should be ignored.

16.
Journal of Medical Postgraduates ; (12)2004.
Article in Chinese | WPRIM | ID: wpr-590949

ABSTRACT

Objective: To investigate the hemodynamic changes of ophthalmic artery(OA) and central retinal artery(CRA) in patients with primary angle-closure glaucoma(PACG) and the effects of intraocular pressure(IOP) on retrobulbar hemodynamics. Methods: Following the measurement of IOP by non-contact tonometry,hemodynamic changes of OA and CRA were examined by color Doppler imaging(CDI) in 45 patients(90 eyes) with PACG,who were divided according to IOP into a hypertension(38 eyes) and a normal tension group(52 eyes).Observations were made of the peak systolic velocity(PSV),end-diastolic velocity(EDV),pulsatility index(PI) and resistance index(RI).Results: Significant differences were found between the PACG patients and the normal controls in CRA-EDV(P

17.
Journal of Medical Postgraduates ; (12)2003.
Article in Chinese | WPRIM | ID: wpr-592416

ABSTRACT

Arterial stenosis-induced hemodynamic changes and their evaluation have long been studied by lots of scholars by in vivo and in vitro experiments,clinical observation and improved experimental devices and methods,which has contributed a lot to the diagnosis and treatment of arterial stenosis.This review describes the current research results.

18.
Journal of Medical Postgraduates ; (12)2003.
Article in Chinese | WPRIM | ID: wpr-591714

ABSTRACT

Objective:To evaluate the characteristics of contrast-enhanced ultrasonography in renal VX2 tumors.Methods: VX2 tumors were transplanted into 12 rabbit kidneys and observations were made by contrast-enhanced ultrasonography 7,14 and 21 days after the transplantation respectively.Results: The best intervention time was 2-3 weeks after the tumor transplantation,while nicrosis was apt to occur after 3 weeks.The visibility of the renal tumors was significantly increased from 57.1%(12/21) to 100%(21/21).Contrast-enhanced ultrasonography showed defect and delineation of VX2 tumors. Conclusion: Contrast-enhanced ultrasonography can improve the peripheral and internal blood flows of the tumors promote the diagnosis of renal tumors.

19.
Journal of Medical Postgraduates ; (12)2003.
Article in Chinese | WPRIM | ID: wpr-594224

ABSTRACT

Objective:Patients with obstructive sleep apnea syndrome (OSAS) often had severe cardiovascular complications. So the early detection of the cardiovascular functional abnormality was more and more thought highly of by people. We evaluated the cardiac function of the patients with (OSAS) using tissue Doppler imaging (TDI) technique. Methods:Thirty-five patients with OSAS and 35 healthy controls were enrolled in the study. TDI was applied in the pulse-Doppler mode to allow for a spectral display and recording of mitral annulus at septal,lateral corner and tricuspid lateral corner in the apical four chamber view. The peak systolic (Sm),early diastolic (Em) and late diastolic (Am) TDI velocity both of mitral and tricuspid annulus were measured by pulsed wave tissue Doppler imaging technique. Results:There were significant differences in Sm of mitral lateral corner,in Sm,Em and Em to Am ratio of mitral septal corner and in Sm,Em,Am and Em to Am ratio of tricuspid lateral corner between the OSAS group and healthy control group (P

SELECTION OF CITATIONS
SEARCH DETAIL